4.1301.13b
Rigid
air barrier
Air barrier
The separation between the interior and exterior environments of a building that slows air flow to the point that no smoke movement is visible at 50 pascals of pressure difference across the boundary
A rigid
air barrier
Air barrier
The separation between the interior and exterior environments of a building that slows air flow to the point that no smoke movement is visible at 50 pascals of pressure difference across the boundary
will be mechanically fastened to underside of floor assembly
Seams and penetrations will be sealed
Rigid barrier will be resistant to pests
At minimum, all gaps larger than 1/4" x 1/4" will be stuffed with copper metal mesh or other rodent-proof material
If rodents can easily get their mouth around corners, they will be reinforced with hardware cloth or metal angle (e.g., gypsum board bead)
Relocate
air barrier
Air barrier
The separation between the interior and exterior environments of a building that slows air flow to the point that no smoke movement is visible at 50 pascals of pressure difference across the boundary
4.1301.13c
Installation Loose-fill insulation will be installed between
air barrier
Air barrier
The separation between the interior and exterior environments of a building that slows air flow to the point that no smoke movement is visible at 50 pascals of pressure difference across the boundary
and subfloor in accordance with manufacturer specifications to achieve required density, maintain consistent coverage, and achieve specified R-value
Insulation will be installed to prescribed R-value
Insulate to prescribed R-value
4.1301.13d
Building operations staff education A dated receipt signed by the installer will be provided that includes:
Insulation type
Coverage area
R-value
Installed thickness and minimum settled thickness
Number of bags installed in accordance with manufacturer specifications Document job completion to contract specifications
Confirm amount of insulation installed
Ensure ability to match bags required for total area completed
Comply with 16 CFR 460.17