4.1006.3a
Installation Sides of fan insulation box assembly will be insulated to the same R-value as adjoining insulated assembly
Insulate to prescribed R-value
4.1006.3b
Air sealing Fan insulation box frame will be continuously weatherstripped to ensure a tight fit
Fan insulation box will be constructed at a depth to protect the fan housing and motor from insulation
Prevent air leakage
4.1006.3c
Attachment Non-compressible insulation will be permanently attached in contact with fan insulation box
Appropriate adhesive or mechanical fastener will be used
Ensure continuous alignment with
air barrier
Air barrier
The separation between the interior and exterior environments of a building that slows air flow to the point that no smoke movement is visible at 50 pascals of pressure difference across the boundary
4.1006.3d
Durability Material integrity will meet a minimum expected service life of 20 years
Ensure a minimum expected service life
4.1006.3e
Occupant education Purpose of insulation will be communicated to occupant
Educate occupant on how to use the whole-house fan to ensure integrity of the fan insulated assembly throughout service life