4.1003.4a
Vapor barrier
Vapor barrier
A material that retards the passage of water vapor and contains a perm rating of less than 1
removal Vapor barriers will be removed from existing attic floor
Ensure the new conditioned space is coupled with the house
4.1003.4b
Netting, fabric, rigid sheathing When using netting or fabric, staples will be placed in accordance with manufacturer specifications, whichever is more stringent
Netting or fabric will meet local fire codes
Rigid materials will close the cavity
Secure insulation
4.1003.4c
Installation Roof cavities will be dense packed with loose fill insulation in accordance with manufacturer density specifications
Insulation will be installed to prescribed R-value
Insulate to prescribed R-value
4.1003.4d
Onsite documentation A dated receipt signed by the installer will be provided that includes:
Insulation type
Coverage area
R-value
Installed thickness and minimum settled thickness
Number of bags installed in accordance with manufacturer specifications Document job completion to contract specifications
Confirm amount of insulation installed
Ensure ability to match bags required for total area completed
Comply with 16 CFR 460.17
4.1003.4e
Occupant education Documentation of material and R-value will be provided to occupants
Provide occupant with documentation of installation