| 3.1302.1a
Work assessment | Installer prework assessment will be conducted to determine: - Accessibility
- Number
- Type
- Size
- Operating condition
- Condition of opening
- Wall construction type
| Ensure work space is safe and ready for air sealing Verify scope of work |
| 3.1302.1b
Lead paint assessment | Presence of lead-based paint in pre-1978 homes will be assumed unless testing confirms otherwise; documentation of testing results will be kept on file
EPA
EPA
U.S. Environmental Protection Agency, www.epa.gov
's Renovation, Repair and Painting (
RRP
RRP
Renovation, repair, and painting
) Program Rule (40 CFR Part 745) in pre-1978 homes and proposed changes to this rule (Federal Register/Vol. 75, No. 87/May 6, 2010) will be complied with, to be superseded by any subsequent final rulemaking or any more stringent state or federal standards | Protect worker and occupant from potential lead hazards |
| 3.1302.1c
Air
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
| Details that reduce air
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
will be repaired, replaced, sealed, or installed Bay window floor framing that connects interior to exterior underpinning and insulation must be removed to seal gaps, cracks, and joints Blocking must be installed on perimeter rail (rim joist) if missing Seal all gaps, cracks, and joints of all framing in bay window assembly Insulation must be replaced or installed in full contact with subfloor Underpinning will be replaced and sealed | Reduce air
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
|
| 3.1302.1d
Water
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
| Details that reduce water
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
will be repaired, replaced, or installed | Reduce water
infiltration
Infiltration
The uncontrolled passage of outside air into a building through unintended leaks in the building envelope
|