| 2.0103.2a
Worker safety | Follow all worker safety specifications in SWS 2.0100 Global Worker Safety section | Prevent injury Minimize exposure to health and safety hazards |
| 2.0103.2b
Mercury | When replacing existing thermostats, identify and dispose of any mercury containing thermostats in accordance with Environmental Protection Agency (
EPA
EPA
U.S. Environmental Protection Agency, www.epa.gov
) guidance | Protect worker and occupant from mercury exposure |
| 2.0103.2c
Asbestos | Suspected asbestos hazards will be identified in furnaces (e.g., gaskets), wood stoves, zonal heating devices, electrical wiring insulation, boilers, and pipe insulation and corrected in accordance with
EPA
EPA
U.S. Environmental Protection Agency, www.epa.gov
guidance Workers will take precautionary measures to avoid exposure | Protect worker and occupant from asbestos exposure |
| 2.0103.2d
Personal protective equipment (
PPE
PPE
Personal protective equipment
) | Workers will wear personal protective equipment (
PPE
PPE
Personal protective equipment
) as needed to protect themselves against exposure to hazards (e.g., pests, sewage, flooded duct work, mold, chemicals, scat, viruses) Long sleeves and long pants should be worn as additional protection from liquid nitrogen and other hazardous materials | Protect worker from exposure to hazards Protect worker from skin contact with liquid nitrogen |
| 2.0103.2e
Combustible gas detection | Worker will check for presence of combustible gas leaks before work begins Leaks will be repaired before work is performed | Protect worker and occupant from exposure to hazards |
| 2.0103.2f
Carbon monoxide (
CO
CO
Carbon monoxide
) | Workers will check for presence of ambient
CO
CO
Carbon monoxide
before and during work
CO
CO
Carbon monoxide
issues will be addressed before work is performed or continued | Protect worker and occupant from exposure to hazards |
| 2.0103.2g
Sealant | Pipes will be sealed by a certified professional with an approved fastening process and sealant in accordance with manufacturer specifications (International Fuel Gas Code) Gas lines will be leak free when tested with an electronic combustible gas leak detector and verified with bubble solution OR Gas lines will be leak free when tested by a standing pressure test that meets the approval of the local code | Install gas lines with no leaks |
| 2.0103.2h
Safety devices | A secondary LP safety detector system (valve, exhaust fan, alarm light) will be installed by a certified professional for propane piping installed below grade When installing new equipment, a shut off valves will be installed by a certified professional at each gas appliance (
ANSI
ANSI
American National Standards Institute, www.ansi.org
Z21.15) | Detect accumulation of dangerous levels of propane in below-grade areas Isolate appliances from the rest of the system for emergencies, removal, or repairs |