FavoritePlease sign in to add this to your favorites. Topic: Attics Subtopic: Special Considerations For supporting material, see Building America Solution Center. Desired Outcome: Radiant heat flow reduced Single-Family HomesPrintCopy to ExcelEmail TitleSpecification(s)Objective(s) 4.1088.2a Stapling An air space no less than ¾" will be maintained between the barrier and the bottom of the roof deck Ensure performance of radiant barrier 4.1088.2b Ventilation A minimum of 3" clearance from soffit vents and ridge vents will be maintained Allow for air flow behind barrier 4.1088.2c Gable walls Radiant barrier will apply to gable walls while maintaining a ¾" air spaceRadiant barrier will not block gable vents Ensure performance of radiant barrier 4.1088.2d Porch and garage attic spaces Radiant barrier will be installed to separate the attic above conditioned space from adjacent atticsRadiant barrier will be installed to withstand local wind loads Reduce radiant heat entryEnsure durability 4.1088.2e Onsite documentation A dated receipt signed by the installer will be provided that includes: Number and thickness of air spaces R-value Direction of heat flow Document job completion to contract specifications Comply with 16 CFR 460.17 Previous Detail Next Detail Back to 4.1088 Special Considerations Back to Top